
Particle Technology Labs
Downers Grove, IL, United States particletechlabs.com From their website, Nov 2026
- ISO 17025
Work here? Claim this listing
About
Particle Technology Labs performs particle characterization testing and advisory work for clients in pharmaceutical, industrial, public sector, and scientific organizations. It is based in North Aurora, Illinois, and serves customers across many industries with analytical testing methods for particle size, surface area, porosity, cleanliness, and related properties.
Particle Technology Labs is a test lab in Downers Grove, IL. It lists 30 services, including Particle Size Distribution, Laser Diffraction and Single Particle Optical Sensing (SPOS) / Light Obscuration. It names ISO 17025 on its listing. It works with apis, excipients and flyash.
Services
Particle Size Distribution
Measures and reports the size and range of particles in a sample using a technique chosen for the sample properties and testing objective.
Laser Diffraction
Uses laser scattering on dry or liquid dispersions to generate particle size distributions.
Single Particle Optical Sensing (SPOS) / Light Obscuration
Counts and sizes particles in liquid suspensions using light extinction and light scattering.
Dynamic Light Scattering (DLS)
Analyzes sub-micron suspended material to determine average particle size and polydispersity.
Electric Sensing Zone
Uses a conductive fluid and precision aperture to count particles and determine size distribution and envelope volume.
Nanoparticle Tracking Analysis (NTA)
Tracks individual suspended sub-micron particles to generate a high-resolution particle size distribution.
Particle Size and Shape Analysis / Image Analysis
Captures images of dispersed particles to report size and shape parameters such as diameter, aspect ratio, circularity, and convexity.
Sieve Analysis
Separates and classifies sample particles by passing material through a stack of sieves with decreasing openings.
22 more services
- Morphologically Directed Raman Spectroscopy (MDRS)
- Automatic Particle Counter (APC) Analysis
- Adsorption & Porosimetry
- Chemisorption
- Dynamic Vapor Sorption
- Water Activity
- BET Specific Surface Area Testing
- Capillary Flow Porometry
- Micropore Measurement
- Mesopore Analysis
- Mercury Intrusion Porosimetry
- Particle Identification / Speciation
- Scanning Electron Microscopy (SEM)
- Thermal Analyses
- Thermogravimetric Analysis (TGA)
- Differential Scanning Calorimetry (DSC)
- Zeta Potential Analysis
- Density Analysis
- Rheology and Dynamic Viscosity
- Refractive Index (RI)
- Digital Microscopy
- USP 788 Particulate Matter in Injectables
- Lead time
- 24-48 hours
- What to send
- Submit Sample Request form
- Quote request form
- Client-provided test methods for method evaluation
- Samples submitted through the request quote form
- Minimums and prices
- For urgent matters, call (630) 403-0099 or use the Live Chat feature
How to order from Particle Technology Labs
What to send, as they list it: Submit Sample Request form; Quote request form; Client-provided test methods for method evaluation; Samples submitted through the request quote form. Minimums and prices they state: For urgent matters, call (630) 403-0099 or use the Live Chat feature. Lead time they state: 24-48 hours. They take quote requests through a form on their website. You can contact them directly from this page, or request a quote through Midgard.
Capabilities
- Processes
- Laser diffraction
- Static light scattering
- Single particle optical sensing
- Light obscuration
- Dynamic light scattering
- Electric sensing zone
14 more
- Nanoparticle tracking analysis
- Image analysis
- Sieve analysis
- Morphologically directed Raman spectroscopy
- Gas adsorption
- Chemisorption
- Dynamic vapor sorption
- Water activity measurement
- BET specific surface area testing
- Particle size distribution
- Morphologically directed Raman spectroscopy (MDRS)
- Automatic particle counter (APC) analysis
- Adsorption and porosimetry
- Water activity
- Capacity
- Over 40 analytical testing techniques
- Broad dynamic range from submicron to millimeters for laser diffraction
- 1 nanometer to 1 micron for DLS
- Low sample quantities are suitable for analysis for Electric Sensing Zone
- Work on broad distributions and/or low concentration samples for NTA
- Receives an average of 350 samples per week
Equipment
- Laser diffractors
- Tunable diode laser
- Platinum electrode
- Precision aperture
- Digital microbalance
- CCD camera
4 more
- Scanning electron microscopy (SEM)
- Raman spectroscopy
- BET instrumentation
- Mercury intrusion porosimetry instrumentation
Materials
- APIs
- Excipients
- Flyash
- Wastewater
- Environmental emission samples
- Injectable suspensions
12 more
- Ophthalmic solutions
- Industrial oils
- Slurries
- Emulsion droplets
- Exosomes
- Liposomes
- Virosomes
- Hydraulic fluid
- Aviation hydraulic fluid
- Pharmaceutical talc
- Pyrotechnic materials
- Controlled substances
Certifications
As the company states them, with the certificate or registry record where there is one.
FDA registrationListed in FDA database
Listed in the FDA registration database as of Nov 2026
Scope: FDA Establishment Identifier (FEI) · Issued by U.S. FDA · No. 1000305894
ISO/IEC 17025:2017Self-reported
As listed: ISO/IEC 17025:2017 (accredited)
Industries served
- Aerospace
- Agriculture
- Automotive
- Batteries
- Beauty and Cosmetic
- Ceramics
4 more
- Chemical Defense
- Environmental
- Food and Beverage
- Ink, Pigment and Paint
Details
- Type
- Test lab
- Address
- 555 Rogers Street, Downers Grove, IL, 60515
- Serves
- International, United States
- Phone
- 630-969-2703
Public records
- FDA establishment
- 1000305894