Beacon Environmental
Bel Air, MD, United States beacon-usa.com From their website, Nov 2026
- ISO 17025
Work here? Claim this listing
About
Beacon Environmental is an environmental testing laboratory that analyzes soil gas, indoor air, ambient air, sewer gas, and emissions data for vapor intrusion and air quality investigations. It serves environmental consultants, managers, government agencies, and commercial clients in the United States and internationally from its Bel Air, Maryland location.
Services
Passive Soil Gas Surveys
Collects and analyzes time-integrated soil gas samples to identify VOCs and SVOCs and support site characterization and remediation planning.
Vapor Intrusion Monitoring
Monitors indoor air and vapor intrusion pathways in buildings over or near contaminated soil or groundwater.
Passive Air Samplers
Uses passive sorbent samplers to collect VOC and SVOC samples in indoor, outdoor, ambient, and crawlspace air.
Passive Sewer Gas Sampling for Vapor Intrusion Investigations
Provides passive sewer gas sampling and analysis to evaluate vapor intrusion preferential pathways in sewer lines, drains, and underground conduits.
Perimeter Air Quality Monitoring
Monitors VOC emissions around site or facility boundaries, including emissions related to remediation activities and petroleum refineries.
- Lead time
- 7 business days
- 10 business days
- What to send
- Project information for a proposal request
- Site or project name/ID
- Site location
- Project objectives
- Number of sample locations
- Percent covered by asphalt/concrete
- Number of trip blanks
Capabilities
- Processes
- Passive soil gas sampling
- Vapor intrusion monitoring
- Passive air sampling
- Passive sewer gas sampling
- Perimeter air quality monitoring
- Thermal desorption
4 more
- Gas chromatography/mass spectrometry
- Sample analysis
- Data interpretation
- Reporting
- Capacity
- Samples collected over hours, days, or weeks
- Typical 7 to 14 days
- Results in 7 business days
- Reports typically in 10 business days
- More than 45 countries across all 7 continents
Equipment
- BeSure Sample Collection Kit
- BeSure Plug™
- GC/MS instruments
Materials
- Soil gas
- Ambient air
- Indoor air
- Sewer gas
- VOCs
- SVOCs
- Benzene
Certifications
As the company states them, with the certificate or registry record where there is one.
ISO/IEC 17025:2017Self-reported
Scope: analysis of soil gas and air samples
Details
- Type
- Test lab
- Founded
- 1999
- Address
- 526 Underwood Lane Bel Air, MD 21014 USA
- Serves